Utrasound as a method for confirming the positioning of enteral catheters in critically ill patients

Authors

  • Ronan de Souza Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil
  • Cecilia Gómez Ravetti Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, Bed Management Team, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil
  • Rafael Silva e Castro Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, Brazil
  • Elio Furbino Frossard Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, Brazil
  • Isabella Santanna dos Anjos Bed Management Team, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil
  • Angélica Gomides dos Reis Gomes Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil
  • Paula Frizera Vassallo Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil
  • Vandack Nobre Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil

DOI:

https://doi.org/10.11152/mu-4392

Keywords:

enteral nutrition, ultrasound, gastrointestinal intubation, nasoenteral catheter

Abstract

Aim: To evaluate the agreement between the bedside ultrasound in a single epigastric window and the plain X-ray to confirm the positioning of the enteral catheter in critically ill patients.

Material and methods: This was an observational, cross-sectional study conducted in two Intensive Care Units of a university hospital. The ultrasound exams were carried out immediately after the introduction of the enteral catheter, using only the epigastric window, with an injection of 5 ml of air associated with 5 ml of saline solution. In all cases, the plain radiography was taken to confirm the positioning of the enteral catheter and to define the beginning of nutritional therapy.

Results: This study included 83 patients, the positioning of the enteral catheter was confirmed by plain radiography in all cases and by ultrasound in 81 (97.6%) patients. The median duration of the ultrasound exam was 2 (2-3) minutes, while the time spent between the request for the X-ray and the release of the exam for a doctor’s appointment was 225 (120-330) minutes.

Conclusion: Bedside ultrasound proved to be an effective, quick, and safe method to confirm the position of the enteral catheter in critically ill patients.