Qualitative strain elastography – strain ratio evaluation - an important tool in breast cancer diagnostic
DOI:
https://doi.org/10.11152/mu.2013.2066.182.bcdKeywords:
strain elastography, breast tumor, cut-off strain ratioAbstract
Aims: To assess the quality of real time elastography as a differential diagnosis tool for breast nodules and to compare it with standard ultrasonography. Material and methods: In this prospective study we enrolled 174 patients in which 174 dominant breast nodules were considered for the final diagnosis. The results of ultrasonography and real time elastography, both qualitative and quantitative, were compared with pathology findings from the biopsy specimens. Results: Pathology examinations determined 102 nodules were benign and 72 malignant. Qualitative elastography had a better diagnostic performance (82.4% sensitivity and 81.9% specificity) than ultrasonography plus Doppler evaluation (70.3% sensitivity and 73.5% specificity). Quantitative elastography, assessed using the fat-to-lesion ratio, was a good discriminant for malignancy (AUROC = 0.93, p < 0.001). Our results pointed to an optimal threshold for malignancy of > 4.88; by using this threshold, the diagnostic reliability of the fat-to-lesion ratio was better than both ultrasonography and qualitative elastography (86.5% sensitivity and 90.4% specificity). Conclusion: Real time elastography is superior to ultrasonography in diagnosing malignant breast nodules. The evaluation of nodules using a fat-to-lesion ratio was a better discriminant for malignancy than qualitative elastography.
Downloads
Published
Issue
Section
License
All rights are reserved to the Medical Publishing House of the „Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca; no parts of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the permission of the editor.
Correspondence regarding permission to reprint all or part of any article published in this journal should be addressed to the Editor, e-mail: medultrasonography@gmail.com.