Ultrasound measurements and normal values of the liver: a comprehensive review and practical guide

Authors

  • Kathleen Möller Gastroenterology, Sana Hospital Lichtenberg, Berlin
  • Michael Ludwig Department for Internal Medicine, Hospital of the German Armed Forces, Berlin
  • Christian Jenssen Department for Internal Medicine, Krankenhaus Märkisch Oderland, Strausberg, Brandenburg Institute for Clinical Ultrasound (BICUS) at Brandenburg Medical University, Neuruppin
  • Yi Dong Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai
  • Nils Daum Brandenburg Institute for Clinical Ultrasound (BICUS) at Brandenburg Medical University, Neuruppin,Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität Zu Berlin, Department of Anesthesiology and Intensive Care Medicine (CCM/CVK), Berlin
  • Xin Wu Cui Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College and State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Huazhong University of Science and Technology, Wuhan, Hubei
  • Manjiri Dighe University of Washington, Washington
  • Ole Graumann Department of Radiology, Aarhus University Hospital
  • Michael Kallenbach Klinik für Gastroenterologie, Hepatologie und Infektiologie, Universitätsklinikum Düsseldorf
  • Claudia Lucius Outpatient Department of Gastroenterology, IBD center Helios Hospital Berlin Buch, Berlin
  • Roxana Șirli Department of Internal Medicine II – Gastroenterology and Hepatology, Center of Advanced Research in Gastroenterology and Hepatology, "Victor Babeș" University of Medicine and Pharmacy Timișoara
  • Constantinos Zervides CZMH Medical Physics and Dosimetry Services LTD. Limassol
  • Christoph Frank Dietrich Department General Internal Medicine (DAIM), Hospitals Hirslanden Bern Beau Site, Salem and Permanence, Bern

DOI:

https://doi.org/10.11152/mu-4576

Keywords:

ultrasound, liver size, measurement, reference values, examination standard

Abstract

Reliable and reproducible sonographic measurements are essential for accurate liver assessment, both in daily clinical practice and in research. Reference values enable clinicians to differentiate between physiological and pathological findings and thus support diagnostic accuracy, follow-up, and therapeutic decision-making. This comprehensive review synthesizes current evidence on normal liver size as assessed by ultrasound, with a particular focus on measurement techniques, standard values, anatomical variants, and the clinical contexts in which these parameters are relevant. Special attention is given to the influence of patient-related factors such as body constitution, sex, age, and ethnicity. The role of right, left, and caudate lobe measurements is discussed in detail, outlining their relevance in conditions such as hepatomegaly, vascular disorders, or post-resection follow-up. Limitations of currently available data are acknowledged, especially regarding interobserver variability and lack of global uniformity. Future priorities include the establishment of consensus-based international reference standards and the integration of emerging technologies, such as artificial intelligence and advanced image analysis tools, to enhance reproducibility, reduce variability, and improve clinical utility. Ultimately, standardized liver measurements should form an integral part of multiparametric ultrasound examinations to optimize patient care.

Downloads

Published

2026-09-23

Issue

Section

Reviews