Multiparametric ultrasound in torsion of the testicular appendages: a reliable diagnostic tool?
DOI:
https://doi.org/10.11152/mu-3206Keywords:
Torsion, Testicle, Appendix, Color Doppler Ultrasonography, ElastographyAbstract
Aim: Torsion of the testicular appendages represents the most common cause of an acute scrotum in prepubertal boys. Its sonographic appearances on gray-scale US and color Doppler US have already been presented in several studies. The aim of this analysis was to expand those already established techniques with strain elastography and thus present typical features of this entity on multiparametric US.
Material and methods: Retrospective analysis of all patients presented to the urological department with an acute scrotum between January 2018 and July 2020 identified eleven patients 6-17 years old (mean, 11.1 years), discharged with the diagnosis torsion of the testicular appendages that were examined with a high-end ultrasound device.
Results: On gray-scale US all patients showed a round lesion with heterogenous echotexture adjacent to the upper pole of the testis/epididymis with a diameter of 4 to 11.1 mm (mean, 7.7 mm). Scrotal skin thickening and a concomitant hydrocele were found in 9 (81.8%) and 7 (63.6%) cases, respectively. On color Doppler images, all torsed appendages were avascular and in 9 (81.8%) patients we observed hyperemia of the adjacent epididymis. Strain elastography showed increased tissue stiffness in all documented images.
Conclusion: Torsion of the testicular appendages has a set of features on multiparametric US. Awareness of this features can facilitate diagnosis of torsion of the testicular appendages and reduce unnecessary surgical
scrotal exploration or unwarranted antibiotic treatment.
Downloads
Published
Issue
Section
License
All rights are reserved to the Medical Publishing House of the „Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca; no parts of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the permission of the editor.