Contrast-enhanced ultrasound guided biopsy of superficial toracoabdominal and neck lesions. Initial experience in 20 patients
Keywords:
superficial tumors, percutaneous biopsy, contrast enhanced ultrasoundAbstract
Aim: In the diagnostic workup of superficial located tumors, percutaneous biopsy plays an important role. However, a successful retrieval of an adequate tissue sample is achievable in only 80-90% of the cases, mainly due to tissue inhomogenities. Contrast-enhanced ultrasound (CEUS) was successfully used to optimize the percutaneous biopsy in several tumors. The aim of our study was to assess the feasibility of CEUS as a direct guiding method for percutaneous biopsy of superficial toracoabdominal and neck tumors. Material and methods: Twenty patients aged 12-75 years with superficial toraco-abdominal and neck masses were studied. CEUS guided biopsy was performed using the contrast harmonic imaging technique with 9 MHz broadband linear transducer (10 cases) or 3.5MHz transducer (10 cases). The needle (18 G Bard coupled on an automatic device Bard Magnum) was directed in arterial phase into the enhanced, perfused areas. The following parameters were recorded: maximal length of the tumor, perfusion pattern, number of passages, length of the specimen, rate of complications. Results: The mean maximal length of the tumor was 6.95 cm (range 4-10.6 cm). CEUS guided biopsy was technical successful in 100% of patients. The mean number of passages needed to sample a good specimen was 1.6, range 1-3. The mean length of the specimen was 1.18 cm, range 0.8-1.4cm. The perfusion patterns of the tumors in our series were: P1-non-enhancing mass- 11.1 %, P2 peripherally enhancing mass with non-enhancing central area -5.6%, P3 diffusely enhancing mass with scattered non-enhancing areas -77.7 % and P4 completely homogeneously enhancing masses -5.6% of patients. The sensitivity of CEUS guided biopsy in the diagnosis of superficial tumors was 100%. For adenopathies a sub-typing was possible in all cases. There was only one minor hematoma around the punctured tumor in one patient. Conclusions: In our series 83% of the tumors had a perfusion pattern (P2 and P3) that may lead to sampling errors in case of US guided biopsy. CEUS guided biopsy of toracoabdominal and neck tumors is a feasible technique that improves the sensitivity of percutaneous biopsy to 100%.Downloads
Published
Issue
Section
License
All rights are reserved to the Medical Publishing House of the „Iuliu Hatieganu" University of Medicine and Pharmacy, Cluj-Napoca; no parts of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the permission of the editor.
Correspondence regarding permission to reprint all or part of any article published in this journal should be addressed to the Editor, e-mail: medultrasonography@gmail.com.


